Hongbin Lin , Pingjuan Ge , Hailiang Xu , Yuhan Duan
2025, 13(1):42-54. DOI: 10.35833/MPCE.2024.000416
Abstract:Currently, the dominant trend in new energy power supply systems is the heterogeneous inverters-paralleled system (HIPS), which is a combination of grid-following (GFL) and grid-forming (GFM) inverters. The dynamic characteristics of different inverters in HIPS and the differences between GFL and GFM inverters undoubtedly increase the difficulty of the stability analysis and coordinated control. This paper establishes an interactive admittance matrix model of HIPS, fully considers the interactive effects among different inverters, and explores the multi-dimensional resonance characteristics of HIPS by utilizing the modal analysis method. To achieve the coordinated control and oscillation suppression among different inverters, a frequency-divided compensation strategy is proposed, which divides the operation modes of HIPS into three categories, i.e., GFM, GFL, and hybrid modes. Specifically, the frequency division boundary is determined based on the resonance characteristics of GFL and GFM inverters, with the operation modes of HIPS being dynamically adjusted according to the harmonic power ratio. Finally, the simulation and experimental results demonstrate that the HIPS can flexibly adjust the operation modes to adapt to the complex conditions after adopting the frequency-divided compensation strategy and suppressing the oscillation frequency ratio to less than 2%, ensuring the safe and reliable operation of HIPS.
Ghazala Shafique , Johan Boukhenfouf , François Gruson , Frédéric Colas , Xavier Guillaud
2025, 13(1):66-78. DOI: 10.35833/MPCE.2024.000822
Abstract:Grid-forming (GFM) converters are recognized for their stabilizing effects in renewable energy systems. Integrating GFM converters into high-voltage direct current (HVDC) systems requires DC voltage control. However, there can be a conflict between GFM converter and DC voltage control when they are used in combination. This paper presents a rigorous control design for a GFM converter that connects the DC-link voltage to the power angle of the converter, thereby integrating DC voltage control with GFM capability. The proposed control is validated through small-signal and transient-stability analyses on a modular multilevel converter (MMC)-based HVDC system with a point-to-point (P2P) GFM-GFM configuration. The results demonstrate that employing a GFM-GFM configuration with the proposed control enhances the stability of the AC system to which it is connected. The system exhibits low sensitivity to grid strength and can sustain islanding conditions. The high stability limit of the system with varying grid strength using the proposed control is validated using a system with four voltage source converters.
Ganghua Zhang , Wang Xiang , Xia Chen , Rui Tu , Xuebo Qiao , Jinyu Wen
2025, 13(1):154-166. DOI: 10.35833/MPCE.2024.00743
Abstract:Diode-rectifier-based high-voltage direct current (DR-HVDC) systems are considered an attractive solution for integrating offshore wind farms (OWFs). Grid-forming (GFM) control with a rational reactive power allocation capability is crucial for the safe operation of numerous wind turbines (WTs). Most typical GFM controls aim to share surplus reactive power of the system equally among WTs, easily rendering capacity overloads for WTs that are outputting high levels of active power. In this paper, a novel GFM control for OWFs is proposed, allowing for adaptively allocating the reactive power according to the actual active power output of WTs. Firstly, the reactive power characteristics of the AC collection networks and WTs are analyzed across a wide wind power range. Then, combining the positive correlation of WT active power with the output AC voltage, a Q-θ type GFM control for WTs is presented. The adaptive reactive power allocation mechanism and the parameter design of the Q-θ based reactive power controller are elucidated, ensuring that WTs with lower active power output contribute more reactive power to the system than WTs with higher active power output. The AC impedance models of WTs under various GFM controls are established to evaluate the impact of different reactive power controllers. Finally, the feasibility of the proposed control is validated in PSCAD/EMTDC, accompanied by stability analysis.
Salman Badkubi , Aliakbar Jamshidi Far , Sumeet S. Aphale
2025, 13(2):710-719. DOI: 10.35833/MPCE.2023.001004
Abstract:Innovative dynamic models for the DC modular multilevel converter (DC-MMC) in rotating dq frame are presented in this paper, which are specifically designed to enhance converter design and stability analysis. Open-loop and closed-loop models are developed using three dq frames, providing a detailed examination of the impact of 2 nd and 3 rd harmonic components on the model accuracy. A novel contribution of this paper is the integration of a 2 nd harmonic current suppression controller (SHCSC) within the closed-loop model, offering new insights into its effects on system stability. The DC-MMC model is further extended by coupling it with high-voltage direct current (HVDC) cables on each side, forming an interconnected system model that accurately represents a more authentic scenario for future DC grids. The proposed model is rigorously validated against PSCAD benchmark model, confirming their precision and reliability. The interconnected system model is then utilized to analyze the influence of cable length on system stability, demonstrating practical applications. The closed-loop model is subsequently employed for stability assessment of the interconnected system, showcasing its applicability in real-world scenarios. Additionally, a damping controller is designed using participation factor and residue approaches, offering a refined approach to oscillation damping and stability optimization. The effectiveness of the controller is evaluated through eigenvalue analysis, supported by simulation results, underscoring its potential for enhancing system stability.
2025, 13(2):720-731. DOI: 10.35833/MPCE.2024.000352
Abstract:The negative-sequence voltage is often caused by the asymmetrical fault in the AC system, as well as the harmonics after the symmetrical fault at the AC side of inverter in line commutated converter based high-voltage DC (LCC-HVDC). The negative-sequence voltage affects the phase-locked loop (PLL) and the inverter control, thus the inverter is vulnerable to the subsequent commutation failure (SCF). In this paper, the analytical expression of the negative-sequence voltage resulting from the symmetrical fault with the commutation voltage is derived using the switching function and Fourier decomposition. The analytical expressions of the outputs of the PLL and inverter control with respect to time are derived to quantify the contribution of the negative-sequence voltage to the SCF. To deal with the AC component of the input signals in the PLL and the inverter control due to the negative-sequence voltage, the existing proportional-integral controls of the PLL, constant current control, and constant extinction angle control are replaced by the linear active disturbance rejection control against the SCF. Simulation results verify the contributing factors to the SCF. The proposed control reduces the risk of SCF and improves the recovery speed of the system under different fault conditions.
Yuhong Wang , Zipeng Tan , Jianquan Liao , Yangtao Liu , Chunsheng Guo , Niancheng Zhou , Qianggang Wang
2025, 13(3):815-826. DOI: 10.35833/MPCE.2024.000138
Abstract:In a DC grid with dedicated metallic return (DMR), the coupling effects among the positive pole, negative pole, and DMR conductors must be considered, which makes fault identification particularly difficult. In addition, the identification of high-impedance faults remains a major challenge for DC grid protection. To address these issues, this study proposes an adaptive single-end protection method for DC grid based on the transient mean value of the current limiting reactor (CLR) modal voltage. First, a fault analysis model of the DC grid with DMR is established using the Clarke transformation. The characteristics of CLR modal voltage are then clarified. A fault pole-selection method based on a novel modulus phase plane is next proposed. A threshold scaling factor based on the differential of DC bus voltage is then constructed to enhance the sensitivity and rapidity of the protection, which can adaptively modify the threshold according to the fault severity. Finally, a simulation model of a four-terminal DC grid with DMR is developed in PSCAD/EMTDC. The speed and reliability of the proposed protection method are verified by simulations and experiments.
Yuansheng Liang , Haoyong Chen , Jiayan Ding , Zheng Xu , Haifeng Li , Gang Wang
2025, 13(3):827-839. DOI: 10.35833/MPCE.2024.000367
Abstract:The single-ended fault location based on travelling waves (TWs) is commonly used for long-distance high-voltage AC transmission lines. However, it relies on high sampling frequency and accurate capturing of the TW head arrival time. Accordingly, this study establishes a transient analytical method for fault location based on the similarity between the transient recorded waveform and output waveforms of analytical calculation model. In the proposed method, fuzzy constraints of fault features are constructed through time-distance and waveform-scaling correlations while considering the deviation factors of the frequency-dependent wave velocity and TW head arrival time. Accordingly, the high-dimensional space of the fitting problem is transformed into a one-dimensional implicit function fitting problem containing only the fault distance, thereby enabling the waveform comparison problem to be quickly solved based on fault TW features. Under the fuzzy constraints proposed in this study, the proposed method requires only a relatively vague identification of the TW head, and the requirements for sampling frequency are also more lenient. In addition, a sliding window scheme is adopted for enhancing the TW morphology characteristics. Finally, the proposed method is tested using PSCAD, and the simulations validate the fault location accuracy of the proposed method.
Jalal Sahebkar Farkhani , Özgür Çelik , Kaiqi Ma , Claus Leth Bak , Zhe Chen
2025, 13(3):840-851. DOI: 10.35833/MPCE.2023.000925
Abstract:Traditional protection methods are not suitable for hybrid (cable and overhead) transmission lines in voltage source converter based high-voltage direct current (VSC-HVDC) systems. Accordingly, this paper presents the robust fault detection, classification, and location based on the empirical wavelet transform-Teager energy operator (EWT-TEO) and artificial neural network (ANN) for hybrid transmission lines in VSC-HVDC systems. The operational scheme of the proposed protection method consists of two loops ①
Weiye Diao , Ao Liu , Jun Mei , Linyuan Wang , Guanghua Wang , Fujin Deng
2025, 13(3):1040-1051. DOI: 10.35833/MPCE.2024.000650
Abstract:Under weak grid conditions, grid impedance is coupled with a control system for voltage source converter based high-voltage direct current (VSC-HVDC) systems, resulting in decreased synchronization stability. Unfortunately, most studies are based on the assumption that impedance ratio (R/X) is sufficiently small to ignore the effects of grid impedance. In this study, we establish a dynamic coupling model that includes grid impedance and control loops, revealing the influence mechanism of R/X on synchronization stability from a physical perspective. We also quantify the stability range of R/X in the static analysis model and introduce a sensitivity factor to measure its effect on voltage stability. Additionally, we utilize a dynamic analysis model to evaluate power angle convergence, proposing a corresponding stability criterion. We then present a method of synchronous voltage reconstruction aimed at enhancing the grid strength. Theoretical analysis shows that this method can effectively mitigate the effects of coupling between grid impedance and the controller under weak grid conditions, ensuring stable operation even under extremely weak grid conditions. Experiments validate the accuracy and effectiveness of the analysis and method.
Jianchao Ma , Xiaoping Zhou , Lingfeng Deng , Lerong Hong , Hanting Peng , Yizhen Hu , Lei Zhang , Fenfen Zhu , Haitao Xia , Honglin Ouyang
2025, 13(3):1102-1112. DOI: 10.35833/MPCE.2024.000148
Abstract:The introduction of fully controlled devices to build hybrid line commutated converter (H-LCC) has become a new idea to solve the commutation failure. However, existing H-LCC has not considered the implementation of a targeted firing angle control strategy during AC faults, with the objective of enhancing their power transmission and fault response performance. For this reason, this paper proposes an optimized control method for firing angle of H-LCC, designated as flexible virtual firing (FVF). This method first analyzes the influence of alterations in firing angle on reactive power, commutation process and associated action paths. By combining prediction and dynamic search, it optimizes the natural commutation process through the utilization of dynamic boundary and minimum commutation area difference. This can mitigate the impact of AC faults on H-LCC and DC system, thereby improving power transmission and defense to commutation failure, which is beneficial for improving the stability of AC/DC power grids. Finally, the simulation results in PSCAD/EMTDC verify the effectiveness of the proposed method.
Njegos Jankovic , Javier Roldán-Pérez , Milan Prodanovic , Jon Are Suul , Salvatore D’Arco , Luis Rouco
2025, 13(4):1420-1431. DOI: 10.35833/MPCE.2024.000057
Abstract:In recent years, transmission system operators have started requesting converter-interfaced generators (CIGs) to participate in grid services such as power oscillation damping (POD). As power systems are prone to topology changes because of connection and disconnection of generators and lines, one of the most important requirements in the design of POD controller is to account for these changes. This can be done by either adjusting the controller structure during the operation or applying a fixed structure designed to address changes in the system. The fixed structure is usually preferred by transmission system operators since it is easier to determine its impact on the system. In this paper, a design procedure is proposed for network-reconfiguration-aware POD controller with fixed structure for CIG-based power plants that considers network configurations with any one line disconnected. The design procedure is based on frequency-response techniques, so it is suitable for application in CIG-based power plants, even in cases when a detailed small-signal model of the system is not available. Designs of a POD controller for the damping of critical system modes can be obtained by using active power, reactive power, or both power components simultaneously. The application to the design of a POD controller for a CIG-based power plant connected to the IEEE 39-bus system is presented as an example. Simulations performed in MATLAB and SimPowerSystems are used to validate the proposed design procedure. The validation includes an analysis of system performance with changes considered in the proposed designed procedure. Also, the system performance under unconsidered changes is examined, covering variations in load and inertia values, as well as disconnection of synchronous generators.
Yifeng Liu , Xiaoping Zhou , Quan Chen , Hanhang Yin , Lerong Hong , Hao Tian , Ying Chen , Siyuan Li
2024, 12(1):287-298. DOI: 10.35833/MPCE.2022.000722
Abstract:Line commutated converter based high-voltage direct-current (LCC-HVDC) transmissions are prone to harmonic oscillation under weak grids. Impedance modeling is an effective method for assessing interaction stability. Firstly, this paper proposes an improved calculation method for the DC voltage and AC currents of commutation stations to address the complex linearization of the commutation process and constructs an overall harmonic state-space (HSS) model of an LCC-HVDC. Based on the HSS model, the closed-loop AC impedances on the LCC-HVDC sending and receiving ends are then derived and verified. The impedance characteristics of the LCC-HVDC are then analyzed to provide a physical explanation for the harmonic oscillation of the system. The effects of the grid strength and control parameters on system stability are also analyzed. To improve the impedance characteristics and operating stability of the LCC-HVDC system, a virtual impedance based stability enhancement control is proposed, and a parameter design method is considered to ensure satisfactory phase margins at both the sending and receiving ends. Finally, simulation results are presented to verify the validity of the impedance model and virtual impedance based stability enhancement control.
Juanjuan Wang , Wei Chen , Yuekun Liu , Chuang Fu , Yunming Ye , Junjie Feng
2024, 12(2):646-657. DOI: 10.35833/MPCE.2022.000702
Abstract:In recent years, high-frequency resonance (HFR) events occurred in several modular multilevel converter based high-voltage direct current (MMC-HVDC) projects. The time delay of an MMC-HVDC system is the critical factor that induces HFR. The frequency coupling affects the impedance characteristics of an MMC and further deteriorates system stability. Therefore, in this paper, a multi-input multi-output admittance model of an MMC-HVDC system is developed to analyze its frequency characteristics. The effects of current loop, power loop, phase-locked loop, and operating point on the MMC frequency coupling degree are analyzed in detail. Meanwhile, to further suppress HFR in the MMC-HVDC system, an enhanced impedance reshaping control strategy based on the equivalent single-input single-output impedance model is proposed. Finally, the accuracy of the enhanced impedance model and the effectiveness of the impedance reshaping control are verified by electromagnetic transient simulations in PSCAD.
Jialiang Wu , Zhen Wang , Ruixu Liu , Yu Shan , Chenxuan Wang
2024, 12(3):958-970. DOI: 10.35833/MPCE.2023.000017
Abstract:Hybrid multi-terminal direct current (MTDC) transmission technology has been a research focus, and primary frequency regulation (FR) improvement in the receiving-end system is one of the problems to be solved. This paper presents a decentralized primary FR scheme for hybrid MTDC power systems considering multi-source enhancement to help suppress frequency disturbance in receiving-end systems. All the converters only need local frequency or DC voltage signal input to respond to system disturbance without communication or a control center, i.e., a decentralized control scheme. The proposed scheme can activate appropriate power sources to assist in FR in various system disturbance severities with fine-designed thresholds, ensuring sufficient utilization of each power source. To better balance FR performance and FR resource participation, an evaluation index is proposed and the parameter optimization problem is further conducted. Finally, the validity of the proposed scheme is verified by simulations in MATLAB/Simulink.
Dalin Mu , Sheng Lin , Xiaopeng Li
2024, 12(3):971-980. DOI: 10.35833/MPCE.2023.000412
Abstract:The hybrid cascaded high-voltage direct current (HVDC) transmission system has various operation modes, and some operation modes are having sharply increasing requirements for protection rapidity, while the traditional pilot differential protection (PDP) has poor rapidity, and even refuses to operate when faults occur on the DC line. Therefore, a novel pilot protection scheme based on traveling wave characteristics is proposed. First, the adaptability of the traditional PDP applied in engineering is analyzed for different operation modes. Then, the expressions of the forward traveling wave (FTW) and backward traveling wave (BTW) on the rectifier side and the inverter side are derived for different fault locations. From the theoretical derivation, the difference between the BTW and FTW on the rectifier side is less than zero, and the same is true on the inverter side. However, in the event of an external fault of DC line, the difference between the BTW and FTW at near-fault terminal protection installation point is greater than zero. Therefore, by summing over the product of the difference between BTW and FTW of the rectifier side and that of the inverter side, the fault identification criterion is constructed. The simulation results show that the proposed pilot protection scheme can quickly and reliably identify the short-circuit faults of DC line in different operation modes.
Yang Wang , Fei Xia , Ying Wang , Xianyong Xiao
2024, 12(4):1327-1332. DOI: 10.35833/MPCE.2023.000093
Abstract:This study presents a harmonic transfer function (HTF) based single-input single-output (SISO) impedance modeling method. The method converts an HTF from phase domain to sequence domain and then transforms it into an SISO impedance while preserving the frequency coupling information of different sequences and different harmonics. Applications of this method to a line-commutated converter based high-voltage direct current (LCC-HVDC) system are presented. The results demonstrate the accuracy of the derived SISO impedance, and a truncation-order selection is suggested. The case study shows that the proposed method facilitates simpler impedance measurements and associated stability analysis.
Shangning Tan , Junliang Liu , Xiong Du , Jingyuan Su , Lijuan Fan
2024, 12(5):1666-1677. DOI: 10.35833/MPCE.2023.000648
Abstract:The voltage source converter based multi-terminal high-voltage direct current (VSC-MTDC) system has attracted much attention because it can achieve the interconnection between AC grids. However, the initial phases and short-circuit ratios (SCRs) of the interconnected AC grids cause the steady-state phases (SSPs) of AC ports in the VSC-MTDC system to be different. This can lead to issues such as mismatches in multiple converter reference frame systems, potentially causing inaccuracies in stability analysis when this phenomenon is disregarded. To address the aforementioned issues, a multi-port network model of the VSC-MTDC system, which considers the SSPs of the AC grids and AC ports, is derived by multiplying the port models of different subsystems (SSs). The proposed multi-port network model can accurately describe the transmission characteristics between the input and output ports of the system. Additionally, this model facilitates accurate analysis of the system stability. Furthermore, it identifies the key factors affecting the system stability. Ultimately, the accuracy of the proposed multi-port network model and the analysis of key factors are verified by time-domain simulations.
Chunyi Han , Lei Shang , Shi Su , Xuzhu Dong , Bo Wang , Hao Bai , Wei Li
2024, 12(5):1678-1689. DOI: 10.35833/MPCE.2022.000738
Abstract:This paper proposes a grid synchronization control strategy for the grid-connected voltage source converters (VSCs) based on the voltage dynamics of the DC-link capacitor in the VSC. The voltage dynamics of the DC-link capacitor are used to regulate the frequency and phase angle of the inner potential of the VSC, synchronizing the VSC with grid. Firstly, in the proposed strategy, the active power regulation and grid synchronization of the VSC are combined, which are separated in the traditional control strategy. This can avoid the instability of the VSC in a weak grid with a low short circuit ratio (SCR), aroused by the dynamic interaction between the separated control loops in traditional control strategies. Secondly, the energy stored in the DC-link capacitor is directly coupled with the grid via the inner potential of the VSC, and the inertia characteristic is naturally featured in the inner potential by the proposed strategy. With the increase of the capacitance, the natural inertial response of the VSC is helpful to improve the grid frequency dynamic. Finally, simulation results are presented to validate the correctness and effectiveness of the proposed strategy on the enhancement of the grid frequency and voltage dynamic support capability.
Jiawei Wang , Graduate , Yujie Sheng , Huaichang Ge , Xiang Bai , Jia Su , Qinglai Guo , Hongbin Sun
2024, 12(6):2006-2018. DOI: 10.35833/MPCE.2024.000139
Abstract:Considering the enormous potential application of autonomous mobility-on-demand (AMoD) systems in future urban transportation, the charging behavior of AMoD fleets, as a key link connecting the power system and the transportation system, needs to be guided by a reasonable charging demand management method. This paper uses game theory to investigate charging pricing methods for the AMoD fleets. Firstly, an AMoD fleet scheduling model with appropriate scale and mathematical complexity is established to describe the spatio-temporal action patterns of the AMoD fleet. Subsequently, using Stackelberg game and Nash bargaining, two game frameworks, i.e., non-cooperative and cooperative, are designed for the charging station operator (CSO) and the AMoD fleet. Then, the interaction trends between the two entities and the mechanism of charging price formation are discussed, along with an analysis of the game implications for breaking the non-cooperative dilemma and moving towards cooperation. Finally, numerical experiments based on real-world city-scale data are provided to validate the designed game frameworks. The results show that the spatio-temporal distribution of charging prices can be captured and utilized by the AMoD fleet. The CSO can then use this action pattern to determine charging prices to optimize the profit. Based on this, negotiated bargaining improves the overall benefits for stakeholders in urban transportation.
Lingxia Lu , Ju-Song Kang , Miao Yu
2024, 12(6):2019-2029. DOI: 10.35833/MPCE.2023.000901
Abstract:Non-intrusive load monitoring (NILM) can provide appliance-level power consumption information without deploying submeters for each load, in which load event detection is one of the crucial steps. However, the existing event detection methods do not efficiently detect both the starting time of an event (STE) and the ending time of an event (ETE), and their adaptability to scenarios with different sampling rates is limited. To address these problems, in this paper, an event detection method based on robust random cut forest (RRCF) algorithm, which is an unsupervised learning method for detecting anomalous data points within a dataset, is proposed. First, the mean-pooling preprocessing is applied to the aggregated load power series with a high sampling rate to minimize fluctuations. Then, the power differential series is obtained, and the anomaly score of each data point is calculated using the RRCF algorithm for preliminary detection. If an event has been preliminarily detected, misidentification caused by fluctuation will be further eliminated by using an adaptive power difference threshold approach. Finally, linear fitting is used to finely and accurately adjust the STE and ETE. The proposed method does not require any pretraining of the detection model and has been validated with both the BLUED dataset (with high and low sampling rates) and the REDD dataset (with low sampling rate). The experimental results demonstrate that the proposed method not only meets real-time requirements, but also exhibits strong adaptability across multiple scenarios. The precision is greater than 92% in distinct sampling rate scenarios, and the F1 score of phase B on the BLUED dataset reaches 94% in the scenario with a high sampling rate. These results indicate that the proposed method outperforms other state-of-the-art methods.
Jie Liu , Shunjiang Lin , Weikun Liang , Yanghua Liu , Mingbo Liu
2024, 12(6):2030-2044. DOI: 10.35833/MPCE.2023.001028
Abstract:As transmission power among interconnected regional grids is increasing rapidly, formulating the power distribution and maintenance schedules of multiple paralleled transmission channels are critical to ensure the secure and economic operation in an AC/DC power system. A coordinated optimization for power distribution and maintenance schedules (COPD-MS) of multiple paralleled transmission channels is proposed, and the active power losses of the resistances of earth line in the high-voltage direct current (HVDC) transmission lines are taken into account when one pole is under maintenance while the other pole is operating under monopolar ground circuit. To solve the proposed COPD-MS model efficiently, the generalized Benders decomposition (GBD) algorithm is used to decompose the proposed COPD-MS model into master problem of maintenance scheduling and sub-problems of power distribution scheduling, and the optimal solution of the original model is obtained by the alternative iteration between them. Moreover, a recursive acceleration (RA) algorithm is proposed to solve the master problem, which can directly obtain its solution in the new iteration by using the solution in the last iteration and the newly added Benders cut. Convex relaxation techniques are applied to the nonlinear constraints in the sub-problem to ensure the reliable convergence. Additionally, since there is no coupling among the power distributions during each time interval in the sub-problem, parallel computing technology is used to improve the computational efficiency. Finally, case studies on the modified IEEE 39-bus system and an actual 1524-bus large-scale AC/DC hybrid power system demonstrate the effectiveness of the proposed COPD-MS model.